Power quality refers to how well the electricity delivered to electrical equipment matches the desired characteristics. It is an essential aspect of electrical power distribution and consumption, and it encompasses a wide range of parameters that impact the performance, reliability, and safety of electrical equipment.
In today’s digitally-driven world, power quality is more important than ever before. Most electrical and electronic equipment in industries, offices, and homes require high-quality power to function correctly. The efficiency and productivity of equipment depend heavily on power quality.
Poor power quality leads to increased downtime, more fault conditions, and, in some cases, complete equipment failure. In addition, machines that rely on high-quality power run more efficiently, reduce energy waste, and decrease the risk of equipment damage, resulting in a significant reduction of operating costs.
The measure of electrical power’s capacity to meet the requirements of the devices, is influenced by multiple factors. Here are some of the significant factors:
Voltage Level
Many electronic devices work within a specific voltage range. Variations in the voltage level can cause the equipment to malfunction and cause power quality problems. Low voltages, for instance, can lead to reduced efficiency, and equipment damage, whereas high voltages can cause overheating and even equipment failure.
Unbalanced Voltage
Unbalanced voltage is a power quality issue where the three phases of a three-phase power system have different magnitudes, creating an asymmetrical waveform. This asymmetry can be caused by unbalanced loads, faulty connections, or phase-to-ground faults.
Unequal voltage levels in different phases of the system can cause unbalanced current flow, leading to overheating of equipment and reduced operating efficiency. Negative or zero-sequence components in the voltage waveform can lead to ground fault current flow, causing damage to equipment and creating safety hazards.
Voltage Sag
Voltage sag or dip is a temporary reduction of voltage below the normal level that lasts for a few cycles to a few seconds. It is caused by a sudden increase in load, a voltage drop in the power grid, or a fault in the system.
Voltage Swell
Voltage swell is a temporary increase in voltage above the normal level that lasts for a few cycles to a few seconds. It is caused by sudden changes in load or when a fault on the system is cleared.
Voltage Interruption
Voltage interruption is a complete loss of voltage for a short period of time. It can be caused by a fault in the distribution system or by lightning strikes, and it can last from a few milliseconds to a few minutes. This interruption can cause equipment to shut down or reset, causing damage or data loss.
Flicker
A flicker is a momentary or sustained variation of voltage characterized by rapid changes in magnitude. It is caused by sudden changes in load, such as the starting of large motors, or by the operation of certain power system equipment like arc furnaces, welding machines, or large drives. The variation in voltage can cause lighting to flicker, which can be noticeable and annoying to occupants. Flicker events are measured by their frequency and depth, and they can impact the performance and lifetime of electronic equipment.
Electrical interference
Interference occurs when noises from other sources, such as other electrical systems, power lines, or even radio transmissions, get mixed in with the electrical signal. Electrical noise can result in signal degradation that can interfere with the equipment’s functioning.
Lack of grounding
Grounding refers to connecting an electrical circuit to the earth. This helps ensure stability, reduce noise and interference, and prevent shocks from electrostatic buildup. Without proper grounding, sensitive electronic equipment can malfunction or become damaged.
Harmonics
Harmonics are higher-frequency electrical signals that contaminate the power delivered by utilities to businesses and homes. Electronic devices with nonlinear loads produce harmonics that can interfere with distribution equipment’s operation and cause damage to electrical equipment.
Power Factor
Power Factor (cosφ) is the relation between apparent power and active power. Inefficient systems tend to have more apparent power than active power, leading to wastage of energy and possibilities of equipment damages.
Transients
Transients refer to sudden and brief fluctuations in voltage or current that occur over a short period of time. They can be caused by events such as lightning strikes, switching operations, or faults in the power system. Transients can range from a few microseconds to several milliseconds in duration, and they can have a significant impact on the operation and reliability of electrical systems and equipment.
Transient voltage surge suppressors, surge protective devices, and other protective measures can be implemented to limit the effects of transients on electrical systems and equipment.
There are several ways to overcome power quality problems. Some of the common solutions are:
Conduct a power quality analysis
The first step to overcome power quality problems is to conduct a power quality analysis. This involves measuring power quality parameters such as voltage, current, frequency, and harmonics to identify any adverse power quality events.
Implement voltage regulation
Installing voltage regulation equipment, such as voltage regulators, stabilizers or transformers, can help regulate voltage fluctuations and maintain a stable power supply.
Use power conditioning equipment
Power conditioners, such as surge protectors, uninterruptible power supplies (UPS), and harmonic filters can help to mitigate the effects of power quality issues.
Use high-quality electrical equipment
Using high-quality electrical equipment, such as motors, transformers, and inverters, can reduce the occurrence of power quality problems.
Improve grounding and bonding
Proper grounding and bonding of electrical systems can help to eliminate ground loops and reduce noise and interference.
Train personnel
Training personnel on power quality issues and how to troubleshoot electrical equipment can help to identify and resolve power quality problems quickly.
Work with a power quality specialist
Consulting with a power quality specialist can help to identify potential power quality problems and provide recommendations for resolving them. Overall, overcoming power quality problems requires a multifaceted approach that includes identifying the root cause of the problem and implementing appropriate corrective measures.
Read more news from Shenzhen Clou
Power quality refers to the level of consistency, reliability, and stability of electrical power. It is important because any deviation from the expected levels of power quality can cause negative consequences such as equipment damage or malfunction, system shutdown, and data loss. Poor power quality can also lead to lower operational efficiency and higher maintenance costs.
Understanding power quality issues and taking measures to maintain good quality power is crucial to ensuring sustainable, safe, and efficient utilization of electrical systems and equipment. Our advanced energy meters, AMI-solutions and test equipment can point you in the right direction. Contact us for specific questions.
Power quality is the measurement of how close to perfect an electrical voltage is at any given time or point. High quality electrical voltage is a sine wave that measures exactly what is expected in both voltage and frequency. A high quality electrical source is one that can deliver all the electrical energy needed without any change in the voltage. In the past, responsibility for power quality was thought to be the power companies’ problem but that isn’t really true. In almost every case, the circumstances that impact power quality are outside of the power companies control.
Historically, most power quality problems were considered to be those things that affected the distribution of power. Lightning, line or transformer failures and/or very high electrical demands (brown outs) on the electrical network are just a few. However, most power quality problems are due to technology changes and the way the electricity is now being used by people.
With each decade, the manufacturers of Power Conditioning and Power Quality equipment are faced with a new set of challenges. As technology changes in all industries, so does the need for ensuring the new technology does not impact the older systems and causing electrical problems. Power quality problems caused by this continued equipment improvement and cost reduction have forced large critical power protection systems to look into the reasons for this change in equipment and their function. There are several facts that will force changes in the technology/topology of power protection systems.
The role of power conditioning systems in the past was to protect the customer's equipment from power quality problems that occurred external to their facility. Today we must also deal with power quality problems caused by their own equipment.
While power requirements are decreasing for individual pieces of equipment, the electrical distortion caused by the newer, more efficient power supplies degrade the performance of the electrical system both inside and outside the facility. Utilities are unable to provide the high quality and reliability in electrical power required to meet the ever increasing power quality standards of newer equipment.
In the 1970's and 1980's, the problems were most felt in large data centers using sensitive computers. Power quality problems were addressed with Uninterruptible Power Systems, Power Distribution Units, and on site Power Generation. In the 1990's, these problems have increased and moved into factories, offices and anywhere solid-state devices are used. The question now is "Can these systems deal with the new types of critical load?" In many cases the answer is, "Not without minor, and in some cases, major design changes."
The issues are becoming more technical and much harder to explain to the design Engineers as they are not aware of changes that will occur after the original build. This document will explain the problems associated with harmonics.
Power quality is a very important issue that should be addressed as poor power quality costs money and in some cases downtime. We will look at some direct and indirect costs attributed to power quality.
Direct cost is the loss of production due to a voltage problem, which trips motor and control devices that stop the manufacturing process. It is the loss of products not produced and the labor charges for removing any damaged materials as well as employee wages paid while waiting for the process to restart.
Indirect cost is the replacement of other equipment that becomes stressed by changing electrical voltages. As an example, a solid-state motor drive fails due to voltage spikes over time. These are commonly caused by power factor capacitors switching on and off line to correct varying power factors. However, the failure and subsequent damage to the machine will be untimely because is not caused by any one spike but by numerous spikes occurring and over a period of time. With this type of power quality damage, it is impossible to avoid the outage.
Nonlinear Loads:
Nonlinear loads cause harmonic distortion, which is the most difficult problem to explain. We need to establish some background on electrical power.
Electrical power in the United States is supplied at 60 hertz (Hz) and is produced by rotating generators. The prime mover for these generators can be hydro (water), steam from coal, oil or nuclear. In all cases, the prime mover changes one type of energy into rotational energy (torque). This rotational energy is then applied to the generator, which turns a magnet in an electrical field. The speeds that the magnet turns determine the frequency of the electrical voltage produced. In the U.S, it is 60 turns each second or 60 Hz. In other countries it may be 50 turns a second (50 Hz).
Each cycle or turn produces a voltage that starts at zero volts and increases to some maximum positive value at ¼ of a revolution (90 °) and then decreases back to zero volts at ½ a revolution (180°). It then increases in a negative direction to a maximum value of ¾ revolution (270°), then decreases back to zero one complete revolution. This is one cycle and is repeated 60 times each second. The voltage waveform is a sine wave and contains 360 electrical degrees.
With a linear load, the current drawn by the load is dependent on the voltage. A linear load is also known as a resistive load. Some examples of resistive loads are heaters and lights.
Each cycle of the generator produces a voltage that varies from zero to maximum. As the voltage increases, the current increases. Think of a dimmer. As you turn the dimmer up, you are increasing the voltages to the light. The increase in voltage causes more current to flow and the light to brighten. If you turn the dimmer the other way, the voltage and current decrease and the light dims. This is a linear response, which is another way of saying the current (light) is a direct response to the amount of voltage.
In the past, most electrical loads were linear loads. This is what made "brownouts" attractive to utilities. If the power company reduced the voltage, the current would decrease as would the total power they demand.
This brings us to nonlinear loads. A nonlinear load is when the amount of current the equipment draws from the utility is not dependent on the utility voltage. One of the very first large nonlinear loads in common use was the static UPS.
The job of the UPS was to provide regulated output voltage to the critical load. When the utility decreased the voltage, the UPS had to compensate. This was accomplished by demanding more current as the utility lowered the voltage. This type of operation is known as a constant kW. One of the key elements of a UPS is to make sure the load never sees a brownout.
The way a UPS compensates for low voltage is to place a very high speed switch between itself and the utility. In large systems, the switch is a SCR, which turns on when the available power is equal to the power required by the load. If the input voltage decreases, the SCR turns on earlier for longer and draws the same amount of power. If there is not enough power, then the UPS uses a battery to make up the difference. In smaller systems, transistors are used in place of SCR's but work the same way.
The nonlinear response just means that the power varies with the load and not the voltage. In a UPS system, and many other high powered nonlinear loads, the switching of the SCR only happens once each voltage cycle.
One of the major advances in power supply design is the switch mode power supply. These new devices cost less, use less power and cause problems. To understand why switch mode power supplies are a problem where older supplies are not, some background on power supplies is necessary. In this section we will explain the differences in the older power supplies as it compares to the power supplies in use today.
The first generations of power supplies were linear. The basic schematic is shown below. A power supply has one purpose, which is to convert the alternating current (AC) furnished by the utility to a direct current (DC) used by the system in which it is installed. A linear supply had four major sections. The first section is the transformer, which will step down (change) the supply voltage to a lower voltage for the computer logic. Typical transformers reduced the 120 VAC supply voltage to 24 volts AC.
The transformed voltage is then sent to rectifiers (diodes) in the second section to convert AC to DC. The DC voltage still had an AC ripple. The rectified voltage was then filtered by the third section to make it usable by the logic. The final filtering of the raw DC voltage was accomplished by the capacitor shown above. The capacitor smoothed the rectified utility voltage to logic grade DC voltage. Logic will not operate correctly without a stable regulated DC supply voltage.
The forth section of the power supply is the voltage regulator. The voltage regulator is a device that compensates for varying supply voltages from the utility. The power tolerance of early computers allowed correct operation from a voltage source This varied from 8% low to 6% high. These variations were common due to changing demands on the utility. Peak loads during air conditioning and heating seasons will cause voltage sags and surges.
The voltage regulator can be looked at the same way as an air regulator on a diver's tank. The diver carries high pressure air in a tank on his back and the regulator reduces the pressure to a level that the diver can breathe. If there were no regulator, the high pressure would cause the diver to explode. The voltage regulator operates the same way. The high DC output from the rectifiers is reduced to a comfortable level for use by the logic. If unregulated DC voltage were given to the computer's logic, it would fail.
The term linear refers to the response of the power supply during input voltage changes. When the input voltage changes, the DC output of the rectifiers will increase or decrease the same percentage as the supply voltage. If the supply voltage increases too much, the raw DC voltage at the input to the regulator can exceed the ability of the regulator to protect the logic from high voltages.
The voltage regulator reduces the unregulated or raw DC to the logic voltage by acting as a valve. For the regulator to operate correctly, the input voltages must always be several volts higher that the logic voltage. In this example, the logic voltage is fifteen volts and the raw DC voltage is 28 volts. For the regulator to work correctly, the input must never fall below 18 volts.
With a minimum DC input voltage of 18 VDC and a voltage tolerance from +6 to -8%, the power supply will operate with a voltage swing of 11 %. This means that the 110 VAC nominal input can vary from 116 VAC to 101 VAC without a problem. If normal variations are greater than the 11 %, a data center will have to install power conditioning. In the first computers, this was the typical power supply and there were problems. The linear supply produced heat and was slow responding to voltage changes. The transformer and voltage regulator both generate heat that could damage the computers' logic if the room was not kept cool.
Advances in voltage regulators and power switching devices made major improvements in the late 1970's and revolutionized the power supply field. As you see in Figure 3 above, the power supply was greatly simplified. The transformers were removed and the voltage regulator was combined with the rectifiers.
The operation was based on the principals that power and not voltage could be regulated. If you will accept that voltage is the same as pressure and current is the same as flow, then power can be looked at as volume. Power is the amount of energy that is used the same way as the amount of water is controlled by the water pressure and how long you open the valve. The higher the voltage (pressure), the more electrons flow (current) and the more energy used.
The new switch mode power supplies operate without a transformer by opening a valve (switch) and letting pluses of current enter the power supply. The switch will turn on several thousand times each second, which greatly improved the ability to respond to changing input voltages. The power supply switch now has many chances to correct the output voltage each cycle. The linear power supply could only react 60 times each second, or once each cycle. The time the switch is on is very short relative to the length of the cycle.
This figure shows a typical output from the switch mode power supply without any filtering. When the switch is on, energy is taken from the source and the voltage increases to the line voltage. When the switch is off, the voltage drops to zero. The addition of a filter allows the power supply to averages out the on and off times to smooth DC voltage for use by the computer's logic. The end result is a power supply that does not need a transformer and can adapt to a wide range of input voltages. The SMPS can adjust the "on" time of the switch to a longer period when the line voltage is low and a shorter "on" time when the line voltage is high.
Switch mode power supplies solved many of the problems that computers suffered with linear power supplies. However, there are problems with electrical systems and power conditioners associated with switching power supplies. The power taken from the electrical source is not drawn evenly. The pulses (on time) occur many times each cycle, at a higher frequency than electrical generators used by the power companies.
The number of "on" periods is known as the pulse repetition rate, and the time the switch is on is the pulse width. The repetition rate is normally at some multiple of the line frequency. This allows an even number of pulses each cycle. The term harmonic refers to the specific multiple of the line frequency that the current is drawn from the source. Figure 6 on the next page depicts how the third harmonic (180 Hz) has three cycles for every one cycle of the fundamental (60 Hz). The seventh harmonic (420 Hz) has seven cycles for every one of the fundamental. If the power supply turns its switch on seven times each cycle, the supply draws' current (power) at the seventh harmonic.
The effect of high frequency power supplies is to strain the electrical system. Transformers, circuit breakers and other electrical devices are designed to operate at a specific frequency. If you look at any piece of equipment, it will have a voltage, frequency and power rating listed on the manufacturers' name plate. When transformers, circuit breakers, UPS and other systems are asked to supply nonlinear currents, their operation can be different from expected.
In the US, the National Electrical Code (NEC) defines the correct (safe) way that electrical systems should be installed. The Electrical Code Board and electrical engineers assume that the electrical systems we connect to the power system are linear and not high frequency. Codes always change due to changes in power supplies, both in data centers and other areas with electronic systems.
The most noticed effect of the high frequencies is heating. The heating occurs in the wires, conduits, circuit breakers and transformers. In data centers, some of the more common problems have been neutral conductors failing. And unexplained opening of circuit breakers and transformer failures.
In the power conditioning industry, we have started to see a common problem. Data centers with power distribution units are running out of places to plug in additional systems. They are running out of pole positions. This shows that the new, smaller devices are filling the power system but not the computer room. This mean that the transformers are running at their design limit The pulse currents cause a problem different problem than just the high frequency issue.
When a switching power supply takes pulses of current and several power supplies all turn on at the same time, peak currents can be very large. However, the average current can be seen by standard metering as within the capability of the power system. The term that defines the peak current (power) is a crest factor.
Figure 7 shows two waveforms. The first is a normal current that most power systems expect, and the second is a pulse that is shorter in time (smaller at the base) but higher in peak. Both waveforms have the same amount of power but one stresses the electrical system more than the other.
Contact us to discuss your requirements of How to Straighten Copper Tubing, Industrial Steel Tube Straightener, Easy to Operate Straightening Machine. Our experienced sales team can help you identify the options that best suit your needs.